WT230 series

13 structural tees sections of nominal size WT230, from CISC Structural Section Tables SST12.1.

WT230 sections
DesignationWeight (kg/m)Depth (mm)Flange (mm)tw (mm)tf (mm)Iₓ (mm⁴)Zₓ (mm³)
WT230×88.588.524128616.626.949,400,000—
WT230×79792382841523.943,500,000—
WT230×727223628313.622.139,000,000—
WT230×535323519412.620.632,800,000—
WT230×646423428212.219.634,500,000—
WT230×48.548.523319311.41929,400,000—
WT230×44.544.523219210.517.727,000,000—
WT230×56.556.523228010.817.330,200,000—
WT230×34342301549.115.421,800,000—
WT230×41412301919.91624,800,000—
WT230×3737229190914.522,400,000—
WT230×3030228153813.318,800,000—
WT230×26262251527.610.816,700,000—