WT230×72
Structural tees from CISC Structural Section Tables SST12.1.
Outline drawn from the published dimensions. Fillets and root radii are not shown.
Dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 236 mm | 9.2913 in |
| Flange width, b_f | 283 mm | 11.1417 in |
| Web thickness, t_w | 13.6 mm | 0.535433 in |
| Flange thickness, t_f | 22.1 mm | 0.870079 in |
Bending about the major axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, Iₓ | 39,000,000 mm⁴ | 93.6979 in⁴ |
| Elastic modulus, Sₓ | 208,000 mm³ | 12.6929 in³ |
| Radius of gyration, rₓ | 65.1 mm | 2.563 in |
| Distance to top fibre | 48.4 mm | 1.9055 in |
| Distance to bottom fibre | 187.6 mm | 7.3858 in |
Bending about the minor axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, I_y | 41,800,000 mm⁴ | 100.4249 in⁴ |
| Elastic modulus, S_y | 295,000 mm³ | 18.002 in³ |
| Radius of gyration, r_y | 67.4 mm | 2.6535 in |
Torsion and warping
| Property | Metric | Imperial |
|---|---|---|
| Torsion constant, J | 1,220,000 mm⁴ | 2.9311 in⁴ |
| Warping constant, C_w | 2.49000e+9 mm⁶ | 9.2725 in⁶ |
Mass
| Property | Metric | Imperial |
|---|---|---|
| Mass per metre | 72 kg/m | 48.5 lb/ft |