WT230×37
Structural tees from CISC Structural Section Tables SST12.1.
Outline drawn from the published dimensions. Fillets and root radii are not shown.
Dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 229 mm | 9.0157 in |
| Flange width, b_f | 190 mm | 7.4803 in |
| Web thickness, t_w | 9 mm | 0.354331 in |
| Flange thickness, t_f | 14.5 mm | 0.570866 in |
Bending about the major axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, Iₓ | 22,400,000 mm⁴ | 53.8162 in⁴ |
| Elastic modulus, Sₓ | 128,000 mm³ | 7.811 in³ |
| Radius of gyration, rₓ | 68.8 mm | 2.7087 in |
| Distance to top fibre | 54.1 mm | 2.1299 in |
| Distance to bottom fibre | 174.9 mm | 6.8858 in |
Bending about the minor axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, I_y | 8,300,000 mm⁴ | 19.9408 in⁴ |
| Elastic modulus, S_y | 87,400 mm³ | 5.3335 in³ |
| Radius of gyration, r_y | 41.9 mm | 1.6496 in |
Torsion and warping
| Property | Metric | Imperial |
|---|---|---|
| Torsion constant, J | 257,000 mm⁴ | 0.617445 in⁴ |
| Warping constant, C_w | 366,000,000 mm⁶ | 1.3629 in⁶ |
Mass
| Property | Metric | Imperial |
|---|---|---|
| Mass per metre | 37 kg/m | 25 lb/ft |