WT230×64
Structural tees from CISC Structural Section Tables SST12.1.
Outline drawn from the published dimensions. Fillets and root radii are not shown.
Dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 234 mm | 9.2126 in |
| Flange width, b_f | 282 mm | 11.1024 in |
| Web thickness, t_w | 12.2 mm | 0.480315 in |
| Flange thickness, t_f | 19.6 mm | 0.771654 in |
Bending about the major axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, Iₓ | 34,500,000 mm⁴ | 82.8866 in⁴ |
| Elastic modulus, Sₓ | 185,000 mm³ | 11.2894 in³ |
| Radius of gyration, rₓ | 64.9 mm | 2.5551 in |
| Distance to top fibre | 47.2 mm | 1.8583 in |
| Distance to bottom fibre | 186.8 mm | 7.3543 in |
Bending about the minor axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, I_y | 36,700,000 mm⁴ | 88.1721 in⁴ |
| Elastic modulus, S_y | 260,000 mm³ | 15.8662 in³ |
| Radius of gyration, r_y | 66.9 mm | 2.6339 in |
Torsion and warping
| Property | Metric | Imperial |
|---|---|---|
| Torsion constant, J | 855,000 mm⁴ | 2.0541 in⁴ |
| Warping constant, C_w | 1.74000e+9 mm⁶ | 6.4796 in⁶ |
Mass
| Property | Metric | Imperial |
|---|---|---|
| Mass per metre | 64 kg/m | 43 lb/ft |