HE 600 B

HE wide flange sections from Eurocode 3 UK National Annex and ArcelorMittal Sections 2026-1.

300 mm600 mm

Outline drawn from the published dimensions. Fillets and root radii are not shown.

Dimensions

PropertyMetricImperial
Depth, d600 mm23.622 in
Flange width, b_f300 mm11.811 in
Web thickness, t_w15.5 mm0.610236 in
Flange thickness, t_f30 mm1.1811 in

Bending about the major axis

PropertyMetricImperial
Second moment of area, Iₓ1.71000e+9 mm⁴4,108.291 in⁴
Elastic modulus, Sₓ5,700,000 mm³347.8353 in³
Plastic modulus, Zₓ6,420,000 mm³391.7724 in³
Radius of gyration, rₓ252 mm9.9213 in
Distance to top fibre300 mm11.811 in
Distance to bottom fibre300 mm11.811 in

Bending about the minor axis

PropertyMetricImperial
Second moment of area, I_y135,000,000 mm⁴324.3388 in⁴
Elastic modulus, S_y902,000 mm³55.0434 in³
Plastic modulus, Z_y1,390,000 mm³84.823 in³
Radius of gyration, r_y70.8 mm2.7874 in

Torsion and warping

PropertyMetricImperial
Torsion constant, J6,770,000 mm⁴16.265 in⁴
Warping constant, C_w1.10000e+13 mm⁶40,962.871 in⁶

Mass

PropertyMetricImperial
Mass per metre212 kg/m142.4574 lb/ft