HE 550 B

HE wide flange sections from Eurocode 3 UK National Annex and ArcelorMittal Sections 2026-1.

300 mm550 mm

Outline drawn from the published dimensions. Fillets and root radii are not shown.

Dimensions

PropertyMetricImperial
Depth, d550 mm21.6535 in
Flange width, b_f300 mm11.811 in
Web thickness, t_w15 mm0.590551 in
Flange thickness, t_f29 mm1.1417 in

Bending about the major axis

PropertyMetricImperial
Second moment of area, Iₓ1.37000e+9 mm⁴3,291.438 in⁴
Elastic modulus, Sₓ4,970,000 mm³303.288 in³
Plastic modulus, Zₓ5,590,000 mm³341.1227 in³
Radius of gyration, rₓ232 mm9.1339 in
Distance to top fibre275 mm10.8268 in
Distance to bottom fibre275 mm10.8268 in

Bending about the minor axis

PropertyMetricImperial
Second moment of area, I_y131,000,000 mm⁴314.7288 in⁴
Elastic modulus, S_y872,000 mm³53.2127 in³
Plastic modulus, Z_y1,340,000 mm³81.7718 in³
Radius of gyration, r_y71.7 mm2.8228 in

Torsion and warping

PropertyMetricImperial
Torsion constant, J6,100,000 mm⁴14.6553 in⁴
Warping constant, C_w8.86000e+12 mm⁶32,993.73 in⁶

Mass

PropertyMetricImperial
Mass per metre199 kg/m133.7218 lb/ft
Analyse a beam with this section