HE 1000 AA

HE wide flange sections from Eurocode 3 UK National Annex and ArcelorMittal Sections 2026-1.

300 mm970 mm

Outline drawn from the published dimensions. Fillets and root radii are not shown.

Dimensions

PropertyMetricImperial
Depth, d970 mm38.189 in
Flange width, b_f300 mm11.811 in
Web thickness, t_w16 mm0.629921 in
Flange thickness, t_f21 mm0.826772 in

Bending about the major axis

PropertyMetricImperial
Second moment of area, Iₓ4.06000e+9 mm⁴9,754.189 in⁴
Elastic modulus, Sₓ8,380,000 mm³511.379 in³
Plastic modulus, Zₓ9,780,000 mm³596.8122 in³
Radius of gyration, rₓ380 mm14.9606 in
Distance to top fibre485 mm19.0945 in
Distance to bottom fibre485 mm19.0945 in

Bending about the minor axis

PropertyMetricImperial
Second moment of area, I_y95,000,000 mm⁴228.2384 in⁴
Elastic modulus, S_y633,000 mm³38.628 in³
Plastic modulus, Z_y1,020,000 mm³62.2442 in³
Radius of gyration, r_y58 mm2.2835 in

Torsion and warping

PropertyMetricImperial
Torsion constant, J3,870,000 mm⁴9.2977 in⁴
Warping constant, C_w2.13000e+13 mm⁶79,319.013 in⁶

Mass

PropertyMetricImperial
Mass per metre222 kg/m149.1771 lb/ft
Analyse a beam with this section