WT75×9

Structural tees from CISC Structural Section Tables SST12.1.

102 mm76.5 mm

Outline drawn from the published dimensions. Fillets and root radii are not shown.

Dimensions

PropertyMetricImperial
Depth, d76.5 mm3.0118 in
Flange width, b_f102 mm4.0157 in
Web thickness, t_w5.8 mm0.228346 in
Flange thickness, t_f7.1 mm0.279528 in

Bending about the major axis

PropertyMetricImperial
Second moment of area, Iₓ544,000 mm⁴1.307 in⁴
Elastic modulus, Sₓ9,160 mm³0.558977 in³
Radius of gyration, rₓ21.8 mm0.858268 in
Distance to top fibre17.1 mm0.6732283 in
Distance to bottom fibre59.4 mm2.3386 in

Bending about the minor axis

PropertyMetricImperial
Second moment of area, I_y629,000 mm⁴1.5112 in⁴
Elastic modulus, S_y12,300 mm³0.750592 in³
Radius of gyration, r_y23.5 mm0.925197 in

Torsion and warping

PropertyMetricImperial
Torsion constant, J18,300 mm⁴0.043966 in⁴
Warping constant, C_w4,740,000 mm⁶0.017651 in⁶

Mass

PropertyMetricImperial
Mass per metre9 kg/m6 lb/ft
Analyse a beam with this section
↑↓ to move · ↵ to open · esc to close⌘K