WT460×195
Structural tees from CISC Structural Section Tables SST12.1.
Outline drawn from the published dimensions. Fillets and root radii are not shown.
Dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 468 mm | 18.4252 in |
| Flange width, b_f | 420 mm | 16.5354 in |
| Web thickness, t_w | 21.3 mm | 0.838583 in |
| Flange thickness, t_f | 36.6 mm | 1.4409 in |
Bending about the major axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, Iₓ | 460,000,000 mm⁴ | 1,105.154 in⁴ |
| Elastic modulus, Sₓ | 1,270,000 mm³ | 77.5002 in³ |
| Radius of gyration, rₓ | 136 mm | 5.3543 in |
| Distance to top fibre | 105 mm | 4.1339 in |
| Distance to bottom fibre | 363 mm | 14.2913 in |
Bending about the minor axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, I_y | 226,000,000 mm⁴ | 542.9672 in⁴ |
| Elastic modulus, S_y | 1,080,000 mm³ | 65.9056 in³ |
| Radius of gyration, r_y | 95.7 mm | 3.7677 in |
Torsion and warping
| Property | Metric | Imperial |
|---|---|---|
| Torsion constant, J | 8,440,000 mm⁴ | 20.2772 in⁴ |
| Warping constant, C_w | 4.96000e+10 mm⁶ | 184.7053 in⁶ |
Mass
| Property | Metric | Imperial |
|---|---|---|
| Mass per metre | 195 kg/m | 131 lb/ft |