WT125×11

Structural tees from CISC Structural Section Tables SST12.1.

102 mm127 mm

Outline drawn from the published dimensions. Fillets and root radii are not shown.

Dimensions

PropertyMetricImperial
Depth, d127 mm5 in
Flange width, b_f102 mm4.0157 in
Web thickness, t_w5.8 mm0.228346 in
Flange thickness, t_f6.9 mm0.271654 in

Bending about the major axis

PropertyMetricImperial
Second moment of area, Iₓ2,270,000 mm⁴5.4537 in⁴
Elastic modulus, Sₓ24,500 mm³1.4951 in³
Radius of gyration, rₓ39.9 mm1.5709 in
Distance to top fibre34.6 mm1.3622 in
Distance to bottom fibre92.4 mm3.6378 in

Bending about the minor axis

PropertyMetricImperial
Second moment of area, I_y613,000 mm⁴1.4727 in⁴
Elastic modulus, S_y12,000 mm³0.732285 in³
Radius of gyration, r_y20.7 mm0.814961 in

Torsion and warping

PropertyMetricImperial
Torsion constant, J21,600 mm⁴0.051894 in⁴
Warping constant, C_w12,600,000 mm⁶0.046921 in⁶

Mass

PropertyMetricImperial
Mass per metre11 kg/m7.5 lb/ft
Analyse a beam with this section