WT100×26
Structural tees from CISC Structural Section Tables SST12.1.
Outline drawn from the published dimensions. Fillets and root radii are not shown.
Dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 103 mm | 4.0551 in |
| Flange width, b_f | 204 mm | 8.0315 in |
| Web thickness, t_w | 7.9 mm | 0.311024 in |
| Flange thickness, t_f | 12.6 mm | 0.496063 in |
Bending about the major axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, Iₓ | 2,000,000 mm⁴ | 4.805 in⁴ |
| Elastic modulus, Sₓ | 23,400 mm³ | 1.428 in³ |
| Radius of gyration, rₓ | 24.5 mm | 0.964567 in |
| Distance to top fibre | 17.5 mm | 0.6889764 in |
| Distance to bottom fibre | 85.5 mm | 3.3661 in |
Bending about the minor axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, I_y | 8,920,000 mm⁴ | 21.4304 in⁴ |
| Elastic modulus, S_y | 87,400 mm³ | 5.3335 in³ |
| Radius of gyration, r_y | 51.8 mm | 2.0394 in |
Torsion and warping
| Property | Metric | Imperial |
|---|---|---|
| Torsion constant, J | 161,000 mm⁴ | 0.386804 in⁴ |
| Warping constant, C_w | 130,000,000 mm⁶ | 0.484107 in⁶ |
Mass
| Property | Metric | Imperial |
|---|---|---|
| Mass per metre | 26 kg/m | 17.5 lb/ft |