C100×7
Channels from CISC Structural Section Tables SST12.1.
Outline drawn from the published dimensions. Fillets and root radii are not shown.
Dimensions
| Property | Metric | Imperial |
|---|---|---|
| Depth, d | 102 mm | 4.0157 in |
| Flange width, b_f | 39 mm | 1.5354 in |
| Web thickness, t_w | 3.2 mm | 0.125984 in |
| Flange thickness, t_f | 7.5 mm | 0.295276 in |
Bending about the major axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, Iₓ | 1,500,000 mm⁴ | 3.6038 in⁴ |
| Elastic modulus, Sₓ | 29,300 mm³ | 1.788 in³ |
| Radius of gyration, rₓ | 41.3 mm | 1.626 in |
| Distance to top fibre | 51 mm | 2.0079 in |
| Distance to bottom fibre | 51 mm | 2.0079 in |
Bending about the minor axis
| Property | Metric | Imperial |
|---|---|---|
| Second moment of area, I_y | 114,000 mm⁴ | 0.273886 in⁴ |
| Elastic modulus, S_y | 4,270 mm³ | 0.260571 in³ |
| Radius of gyration, r_y | 11.4 mm | 0.448819 in |
Torsion and warping
| Property | Metric | Imperial |
|---|---|---|
| Torsion constant, J | 12,900 mm⁴ | 0.030992 in⁴ |
| Warping constant, C_w | 217,000,000 mm⁶ | 0.808086 in⁶ |
Mass
| Property | Metric | Imperial |
|---|---|---|
| Mass per metre | 7 kg/m | 4.5 lb/ft |