125 BT 18

Tees cut from universal beams from Australian-Sections.xlsx (Sheets 1-19).

146.4 mm127 mm

Outline drawn from the published dimensions. Fillets and root radii are not shown.

Dimensions

PropertyMetricImperial
Depth, d127 mm5 in
Flange width, b_f146.4 mm5.7638 in
Web thickness, t_w6.4 mm0.251969 in
Flange thickness, t_f10.9 mm0.429134 in

Bending about the major axis

PropertyMetricImperial
Second moment of area, Iₓ2,900,000 mm⁴6.9673 in⁴
Elastic modulus, Sₓ28,571.429 mm³1.7435 in³
Plastic modulus, Zₓ50,600 mm³3.0878 in³
Radius of gyration, rₓ35.0544 mm1.3801 in
Distance to top fibre25.5 mm1.0039 in
Distance to bottom fibre101.5 mm3.9961 in

Bending about the minor axis

PropertyMetricImperial
Second moment of area, I_y2,850,000 mm⁴6.8472 in⁴
Elastic modulus, S_y38,934.426 mm³2.3759 in³
Plastic modulus, Z_y60,000 mm³3.6614 in³
Radius of gyration, r_y34.7509 mm1.3681 in

Torsion and warping

PropertyMetricImperial
Torsion constant, J77,000 mm⁴0.184993 in⁴

Mass

PropertyMetricImperial
Mass per metre18 kg/m12.0954 lb/ft
Analyse a beam with this section